BRAINFEEDBACK (DEYMED)®
EEG BIOFEEDBACK / DIAGNOSTIC EEG TWO-TAIL
COMPATIBILITY:
EEG Biofeedback ready to upgrade to multichannel EEG
EEG-with-Biofeedback integrated system
Dual Monitor (1 PC) Design for Biofeedback
Guarantees efficient and quiet sessions for both clients and
the therapist.
|
|
The BRAINFEEDBACK Client Software was designed to catch
client's attention very easily. It allows an individual
configuration of video games for each client, adjustable
online during session.
|
|
Five synchronous modalities of feedback
signal:
dynamic (30 games), analog, digital, acoustic, tactile.
|
BRAINFEEDBACK ® Therapist Software
For Windows 95/98/ME/NT/2000/XP:
User-friendly, easy to learn. Automatic CD install takes
5 minutes.
You can operate it within minutes after
installation.
All training records automatically stored in a user-friendly
database. All the clients' saved data available anytime
(even during sessions). The flexible access to documentation
and therapy progress becomes an important part of the
desired quality of your service.
|
|
BRAINFEEDBACK ® Hardware
The latest innovative technology in order to reach the highest
possible reliability. This makes us possible to build smart,
lightweight, efficient and safe systems with a high quality of
signal processing.
Real time impedance measuring combined with FGT (Fast
Gabor Transform) signal processing ensures objective and
precise results. It also escalates therapeutic effects. (If
you prefer classic Fast Fourier Transform, one mouse click can
change it.)
Electrodes' contacts watch
Battery charge online measure
Portable amplifier (pocket size / weight), notebook
adjusted
Supply: 3 cells 1,5 V (AA size) Battery duty duration: 700
hours
SCANNING UNIT TECHNICAL PARAMETERS:
Number of channels (optional): 2 / 4 / 8 / 20 / 24 /
32 / 64 / 128, separate, differential
Frequency Band Width: (+0 -1 dB) 500 Hz
Analog Time Constant: 1s +- 5 % (possible up to 10 s)
Maximum AC Input Range: +- 2 mV
Maximum DC Input Range: +- 140 mV
Equivalent Referred Input Noise: 2uV p-p in 0.16 - 100 Hz band
*
Voltage Measurement Accuracy: +- 2 %
Time Measurement Accuracy: +- 0.1 %
Internaln Analog Sample Rate: 4 096 Hz per channel
Saved Data Sample Rate: 128 - 1024 Hz per channel
High Frequency Reaction: from 525 Hz to 4 kHz: 115 dB / from 4
kHz: 50 dB
Common Mode Rejection Ratio: 120 dB (in frequency band 0 - 60
Hz) **
Input Differential Impedance: 100 GOhm // 35 pF
Input Skin Impedance Range: 0 - 99 kOhm
Measured Impedance Accuracy: +- 10 %
Measurable Transition Impedance: 1 - 50 kOhm
(*) Referred to the average electrode - skin impedance max.
10 kOhm
(**) With difference of input impedance's max. 10 kOhm.
CMRR sufficient for battery run equipment:
Ground electrode connected to a person measures its potential
to the environment perfectly
EEG BIOFEEDBACK PRICES:
|
|
|
2 channels version (2 active EEG):
|
$2,750
|
|
4 channels version (2 active EEG, 1 EMG, 1 GSR):
|
$3,400
|
CE Biofeedback Device Certificate
|
|
|
Delivery time: one week
|
|
|
700+ INSTALLATIONS IN CLINICAL PRACTICES SINCE 1997 Affiliate
Network of AAPB CZ Biofeedback Institute, consisting of
Brainfeedback owners and Training Course graduates, includes
500+ professionals, practicing neurofeedback in 33 countries:
Austria, Belgium, Croatia, Czechia, Denmark, France, Georgia,
Germany, Greece, Guatemala, Hungary, Ireland, Israel, Italy, Lebanon,
Macedonia, Malaysia, Netherlands, Norway, Poland, Portugal, Qatar, Romania,
Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, UAE,
UK, and USA.
INTERESTED? CONTACT:
Dr. Jiri TYL,
Clinical Psychologist, EEG Spectrum Affiliate
Professor of University of New York in Prague
Chair, Biofeedback Institute of AAPB Czech Republic
E-mail: Tyl@centrum.cz
Nikoly Tesly 6, Prague 6, CZ-16000 Czech Republic
Office Phone: +420-233 320 499
Mobile: +420-774 224 962